The main components and accessories of the aluminum-magnesium roofing system have been specially designed to meet the requirements of architects and designers with unique vision.The main components and a wide range of accessories that perfectly match the system give full play to the infinite design potential of the aluminum magnesium manganese roofing system.

Products Details

The main components and accessories of the aluminum-magnesium roofing system have been specially designed to meet the requirements of architects and designers with unique vision. The main components and a wide range of accessories that perfectly match the system give full play to the infinite design potential of the aluminum magnesium manganese roofing system.

The attachment system2

20171219111320133

20171219111327936

20171219111334502

20171219111327936

20171219111334502

  • Waterproof steam permeable film, steam insulation film technical indicators:
type project
Waterproof vapour permeable film
Vapour membrane
standard
enhanced
reflective
thickness (mm)
0.17
0.49
0.18
0.25
density (g/㎡)
61
145
64
108
Permeability of water vapor (g/㎡·24h )≥
(In addition to steam insulation layer
1000
500
200
≤15
watertightness (mm·2h )≥
1000
1500
1000
500
tensile strength (N/50 )≥
endlong
260
315
215
150
across
270
270
180
140
elongation at break (%)≥
endlong
12
11
7
31
across
12
17
11
30
tear strength (N )≥
endlong
40
120
40
210
across
38
130
38
210
  • Moisture proof and steam insulation layer: The steam insulation film is used for the inner surface of the wall or roof insulation layer. It is not permeable to steam and can prevent indoor steam from permeating into the envelope structure, so as to effectively ensure the thermal insulation performance of the thermal insulation material and the durability of the structure. 防潮隔汽层   • heat preservation and insulation layer
category
The main raw material
The density of
kg/m³)
Density values Allowable deviation
%
Coefficient of thermal conductivity (Average temperature 70+5°C
[w/(m∙k)]-2
combustion performance
Thermal load shrinkage temperature
Fiberglass cotton felt principal raw material
12-16
+20
-10
≤0.058
non-ignitable
≥250
20
≤0.053
≥300-350
24-40
≤0.048
rock wool board basalt
61-200
±15
≤0.044
non-ignitable
≥600
  • Sound-absorbing function of glaze felt (without veneer)
  unit weight
  Kg/m³
mm
Test the setup method
The octave center frequency
250
500
1000
2000
NRC
   16
50
A
0.77
1.13
1.09
1.04
1.00
   16
75
A
1.17
1.26
1.09
1.03
1.15
   16
100
A
1.29
1.22
1.06
1.00
1.15
NRC -- Noise Reduction Coefficient Test Setting Method A: Thermal insulation material is bonded to A hard surface such as A brick wall.